| Features |
|
Download datasheet |
- Instant switching AC solid state relay
- 2 input ranges: 3 - 32 VDC and 90 - 280 VAC
- Maximum load current (AC1 at 25° C): 25, 60, 80, 100 A
- Operational ratings: 40 - 480 VAC
- Frequency range: 47 - 63 Hz
- Maximum non-repetitive peak voltage: 1,200 Vp
- LED indicator
- Clip on protective cover for greater safety (IP 20)
|
| Models and references |
| Zero crossing |
Control voltage |
Rated operational voltage |
Rated operational current |
Reference |
| No |
3 - 32 VDC |
40 - 480 VAC |
25 A |
RS1A0P032DC480025R |
| 60 A |
RS1A0P032DC480060R |
| 80 A |
RS1A0P032DC480080R |
| 100 A |
RS1A0P032DC480100R |
| 90 - 280 VAC |
25 A |
RS1A0P280AC480025R |
| 60 A |
RS1A0P280AC480060R |
| 80 A |
RS1A0P280AC480080R |
| 100 A |
RS1A0P280AC480100R |
| General specifications |
| |
VDC input |
VAC input |
| Dielectric insulation (between input and output) |
2,500 VAC |
| Operating temperature |
-30 to 80° C |
| Storage temperature |
-35 to 85° C |
| Rth junction to case |
2.5° C/W (25 A) |
0.3° C/W |
2.5° C/W (25 A) |
0.3° C/W |
| 0.65° C/W (60 A) |
0.65° C/W (60 A) |
| 0.5° C/W (80 A) |
0.5° C/W (80 A) |
| Operating ambient humidity |
Up to 85 % |
| CE marking |
Yes |
| Input specifications |
| |
VDC input |
VAC input |
| Control voltage range |
3 - 32 VDC |
90 - 280 VAC |
| Maximum input current |
13 / 16 mA @= 5 V / 24 V |
29 mA @= 220 V |
| Pick-up voltage |
1.9 VDC |
70 VAC |
| Drop-out voltage |
1.9 VDC |
70 VAC |
| Maximum reverse voltage |
32 VDC |
- |
| Maximum response time pick-up |
1 ms |
| Maximum response time drop-out |
½ cycle |
| Output specifications |
| |
VDC input |
VAC input |
| Maximum load current |
|
|
|
|
| (AC51 at 25° C) |
25, 60, 80 A |
100 A |
25, 60, 80 A |
100 A |
| (AC53a @ Ta = 25° C) |
5, 15, 18 A |
20 A |
5, 15, 18 A |
20 A |
| Load voltage range |
40 - 480 VAC |
| Frequency range |
47 - 63 Hz |
| Maximum non-repetitive peak voltage |
930 Vp |
1,200 Vp |
930 Vp |
1,200 Vp |
| Maximum non-repetitive peak current (t = 10 ms) |
350 Ap / 25 A |
1,100 Ap |
350 Ap / 25 A |
1,100 Ap |
| 630 Ap / 60 A |
630 Ap / 60 A |
| 910 Ap / 80 A |
910 Ap / 80 A |
| Maximum off state leakage current |
8 mArms |
| Minimum off state dv / dt |
200 V / µs |
| Maximum on state voltage |
1.6 VAC |
| Minimum load current |
0.05 Arms |
| I2t (10 ms) (orientative data) |
625 A2s (25 A) |
| 2,025 A2s (60 A) |
| 4,225 A2s (80 A) |
| 6,050 A2s (100 A) |
| Housing specifications |
| Dimensions (L x W x H mm) |
58 x 44 x 23 |
| Weight |
150 g maximum |
| Baseplate |
Aluminum, nickel-plated |
| Control terminal (M3x6) torque |
1.2 Nm |
| Power terminal (M5x9) torque |
2.4 Nm |
| Dimensions |
 |
| Load current vs. ambient temperature |
 |
 |
 |
 |
| Heat sinks |
| Heat sink reference |
Output current |
Dimensions (mm) |
Relays to be used with |
| RSH-059 (DIN-rail) |
≤ 20 A |
44 x 75 x 70 |
RS1A0P032DC480025R |
| RS1A0P280AC480025R |
| RSH-060 |
≤ 20 A |
80 x 50 x 50 |
RS1A0P032DC480025R |
| RS1A0P280AC480025R |
| RSH-061 |
≤ 40 A |
125 x 70 x 50 |
RS1A0P032DC480025R |
| RS1A0P280AC480025R |
| RSH-062 |
≤ 60 A |
125 x 115 x 50 |
RS1A0P032DC480060R |
| RS1A0P280AC480060R |
| RSH-063 |
≤ 100 A |
120 x 80 x 50 |
RS1A0P032DC480080R |
| RS1A0P280AC480080R |
| RS1A0P032DC480100R |
| RS1A0P280AC480100R |
|