| Features |
|
Download datasheet |
- Three phase AC solid state relay, zero crossing
- 2 input ranges: 3 - 32 VDC and 90 - 250 VAC
- Maximum load current (AC1 at 25° C): 25, 60, 80, 100, 120 A
- Operational ratings: 40 - 530 VAC
- Frequency range: 47 - 63 Hz
- Maximum non-repetitive peak voltage: 1,000 Vp
- LED indicator
- Clip on protective cover for greater safety (IP 20)
|
| Models and references |
| Zero crossing |
Control voltage |
Rated operational voltage |
Rated operational current |
Reference |
| Yes |
3 - 32 VDC |
40 - 440 VAC |
25 A |
RS3A0P032DC440025Z |
| 60 A |
RS3A0P032DC440060Z |
| 80 A |
RS3A0P032DC440080Z |
| 120 A |
RS3A0P032DC480120Z |
| 90 - 250 VAC |
25 A |
RS3A0P250AC440025Z |
| 60 A |
RS3A0P250AC440060Z |
| 80 A |
RS3A0P250AC440080Z |
| 40 - 530 VAC |
100 A |
RS3A0P280AC480100Z |
| General specifications |
| |
VDC input |
VAC input |
| Dielectric insulation (between input and output) |
2,500 VAC |
2,000 VAC |
| Operating temperature |
-25 to 70° C |
-40 to 80° C |
| Storage temperature |
-35 to 85° C |
-45 to 85° C |
| Operating ambient humidity |
Up to 85 % |
| CE marking |
Yes |
| Input specifications |
| |
VDC input |
VAC input |
| Control voltage range |
3 - 32 VDC |
90 - 250 VAC |
| Maximum input current |
5/25 mA @= 3 V / 32 V |
5/30 mA @= 90 VAC / 250 VAC |
15/20 mA @= 90 VAC / 250 VAC (only RS3A0P250AC530100Z) |
| Pick-up voltage |
3 VDC |
70 VAC |
| Drop-out voltage |
1 VDC |
70 VAC |
| Maximum reverse voltage |
32 VDC |
- |
| Maximum response time pick-up |
10 ms |
| Maximum response time drop-out |
10 ms |
| Output specifications |
| |
VDC input |
VAC input |
| Maximum load current |
|
|
|
|
| (AC51 @ Ta = 25° C) |
25, 60, 80 A |
120 A |
25, 60, 80 A |
100 A |
| (AC53a @ Ta = 25° C) |
5, 15, 18 A |
21 A |
5, 15, 18 A |
20 A |
| Load voltage range |
40 - 440 VAC |
40 - 530 VAC |
| Frequency range |
50 - 60 Hz |
47 - 63 Hz |
| Maximum non-repetitive peak voltage |
930 Vp |
1,000 Vp |
| Maximum non-repetitive peak current (t = 10 ms) |
350 Ap / 25 A |
1,400 Ap |
350 Ap / 25 A |
1,100 Ap |
| 630 Ap / 60 A |
630 Ap / 60 A |
| 910 Ap / 80 A |
910 Ap / 80 A |
| Maximum off state leakage current |
10 mA |
1 mA |
| Maximum on state voltage |
1.6 VAC |
1.5 VAC |
| Minimum off state dv / dt |
300 V / µs |
| Minimum load current |
0.1 Arms |
| I2t (10 ms) (orientative data) |
625 A2s (25 A) |
| 2,025 A2s (60 A) |
| 4,225 A2s (80 A) |
| 6,050 A2s (100 A) |
| 9,800 A2s (120 A) |
| Housing specifications |
| |
VDC input |
VAC input |
| Dimensions (L x W x H mm) |
105 x 75 x 32 |
120 x 85 x 50 |
| Weight |
500 g maximum |
| Baseplate |
Aluminum, nickel-plated |
| Control terminal (M3x6) torque |
1.2 Nm |
| Power terminal (M5x9) torque |
2.4 Nm |
| Dimensions |
 |
| Load current vs. ambient temperature |
 |
 |
 |
 |
 |
|
| Heat sinks |
| Heat sink reference |
Output current |
Dimensions (mm) |
Relays to be used with |
| RSH-035 |
≤ 20 A |
150 x 90 x 35 |
RS3A0P032DC440025Z |
| RS3A0P250AC440025Z |
| RSH-036 |
≤ 40 A |
150 x 100 x 80 |
RS3A0P032DC440025Z |
| RS3A0P250AC440025Z |
| RSH-037 |
≤ 80 A |
260 x 180 x 50 |
RS3A0P032DC440060Z |
| RS3A0P250AC440060Z |
| RSH-038 |
≤ 100 A |
150 x 125 x 135 |
RS3A0P032DC440080Z |
| RS3A0P250AC440080Z |
| RS3A0P250AC530100Z |
| RSH-039 |
≤ 200 A |
200 x 125 x 135 |
RS3A0P032DC440120Z |
|